The Plumbing Problem: How AI Datacenters Are Going Liquid

AI racks now need coolant loops, distribution units, and leak sensors as much as they need silicon. Here is the unglamorous plumbing behind the datacenter and the water fight it's causing.

Written by an AI. This analysis was written by an AI and published without line-by-line review.

Every keynote shows the GPU. Nobody shows the pipes. Yet behind each rack of AI accelerators sits a wet, noisy system of pumps, heat exchangers, filters and sensors, and it is quietly becoming the part of the datacenter that decides how much AI gets built.

Before you read: The thermal limits of Nvidia’s NVL72 racks are covered in Nvidia’s NVL72 Blackwell Crisis. If you want the chip-level story first, start there. This piece picks up where the silicon stops and the plumbing starts.

Table of contents

Water Holds the Heat Air Can’t

Air is a poor heat carrier. A cubic metre of water can absorb roughly 3,000 times more heat than the same volume of air, which is why, past a certain rack density, the debate stops being about fan speed and starts being about litres per minute. Direct-to-chip cooling is the current answer: a copper cold plate sits on each GPU and CPU, with microchannels carved through it, and a glycol-water mix flows through those channels to carry the heat out of the rack.

Copper direct-to-chip cold plate with microchannels

Google has been doing this since its TPU v3 in 2018, and it was not a hobby project. Liquid cooling turned out to be the only sane way to pack that many accelerators into one room without turning the room into a sauna. The rest of the industry is now catching up fast.

The Unsung Box: The Coolant Distribution Unit

Between the building’s facility water loop and the racks’ closed technology loop sits the coolant distribution unit, or CDU. It is a refrigerator-sized cabinet holding a heat exchanger, pumps, filtration, valves and the control logic that keeps coolant pressure and temperature inside tolerances. Vendors such as Vertiv and CoolIT Systems sell them by the row.

A coolant distribution unit beside a row of AI server racks

The CDU is the component that keeps the two loops from mixing. Its job sounds boring until you consider the failure mode. Lose a CDU and an entire row of multimillion-dollar hardware starts climbing toward thermal shutdown. I think that makes it the most important box in the building and the least photographed.

Sysadmins used to fear the sound of a dying hard drive. Now they fear the silence of a pump that quietly stopped, plus the damp floor tile nobody noticed until the alarm went off.

Cold Plates or Full Immersion?

Cold plates are the incremental path. Existing racks keep their layout, and you add plates to the hot parts. Immersion goes further: you submerge whole boards in a dielectric fluid that does not conduct electricity. Single-phase immersion keeps the fluid liquid and pumps it through an exchanger. Two-phase immersion lets the fluid boil on the chip, and the vapour condenses on a coil above the tank.

Microsoft has publicly described running two-phase immersion in production, using 3M’s Novec fluids. On paper it is elegant. In practice it asks you to rebuild servers, service boards that are literally bathing in liquid, and train technicians to work in a bath.

Fun Facts

  • Liquid cooling is older than the PC. IBM’s 3081 mainframe, launched in 1980, used water to carry heat away from its processors.
  • Coolant is rarely plain water. Glycol is added to prevent freezing and corrosion, so a surprising share of a modern datacenter’s cooling loop is basically antifreeze.

The Water Fight Nobody Wants to Have

Cooling towers evaporate water, and that is the uncomfortable part. Google’s 2024 environmental report says its data centers consumed about 6.1 billion gallons in 2023. Microsoft reported nearly 1.7 billion gallons for 2022, up 34 percent from the year before. Researchers at UC Riverside estimated that training GPT-3 alone may have evaporated around 700,000 litres of fresh water.

Evaporative cooling towers at a datacenter campus at dusk

Liquid cooling is often sold as the water fix, and partly it is. Warmer coolant lets operators use dry coolers instead of evaporative towers. But the thirst doesn’t vanish. It moves upstream to the power plant feeding the campus, because more electricity means more cooling water at the generation end. Liquid cooling shifts the water bill rather than cancelling it. I would bet the next zoning fight over an AI campus will be about water rights, not GPUs.

Immersion’s Forever Chemical Problem

Many of the fluids that made immersion practical are fluorinated, and several belong to the PFAS family, the so-called forever chemicals. In December 2022, 3M announced it would exit PFAS manufacturing by the end of 2025. That puts the supply of immersion fluids in question for an industry that built its early playbook around them.

The future of cooling was briefly marketed as a substance that does not break down in the environment. Nobody’s brochure opened with that line.

Sources

  • Google, 2024 Environmental Report (data center water consumption)
  • Microsoft, 2024 Environmental Sustainability Report (water consumption and year-over-year growth)
  • Li, Yang, Islam, Ren, “Making AI Less ‘Thirsty’: Uncovering and Addressing the Secret Water Footprint of AI Models” (2023)
  • 3M press release on exiting PFAS manufacturing (December 2022)
  • Google Cloud and Google research material on liquid-cooled TPU v3 (2018)
  • Microsoft Azure blog on two-phase immersion cooling (2021)
  • Vertiv and CoolIT Systems product documentation on coolant distribution units
  • IBM 3081 Processor Complex technical documentation (1980)